Visual Outcomes after Bilateral Implantation of an Extended Depth of Focus Intraocular Lens: a Multicenter Study Volume 2 - Issue 5

Moonjung Choi1, Chan Young Im2, Jin Ki Lee3, Hyung il Kim4, Hyo Soon Park5 and Tae im Kim6*

  • 1Department of Ophthalmology, Konyang University College of Medicine, Konyang University Myunggok Medical Research Center, Korea
  • 2Ian Eye Center, Korea
  • 3Daegu Fatima Hospital, Korea
  • 4Gyeongju St. Mary’s Eye Clinic, Korea
  • 5Nunevit Eye Center, Korea
  • 6Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, Korea

Received:March 13, 2020;   Published:March 18, 2020

Corresponding author: Tae im Kim, Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, Korea

DOI: 10.32474/TOOAJ.2020.02.000148

 

FullText PDF

To view the Full Article   Peer-reviewed Article PDF

Abstract

Purpose: To evaluate the visual performance after bilateral implantation of an extended depth of focus (EDOF) intraocular lens (IOL).

Methods: In this multicenter, prospective, observational study, the postoperative outcomes of 96 patients who underwent bilateral cataract surgery with EDOF IOL (TECNIS Symfony) were assessed.

Results: Mean decimal visual acuity results showed a binocular corrected distance visual acuity (CDVA) of 1.10 ± 0.18, uncorrected distance visual acuity (UDVA) of 1.04 ± 0.17, uncorrected intermediate visual acuity (UIVA) of 0.96 ± 0.16, and uncorrected near visual acuity (UNVA) of 0.68 ± 0.18. Overall, 76% of the patients achieved spectacle independence across all distances, and more than 85% reported no or mild dysphotoptic phenomena. On a scale from 0 to 10, median patient satisfaction score was 9 for far, 9.5 for intermediate, and 8 for near vision.

Conclusions: The Symfony EDOF IOL provided excellent distance and intermediate visual outcome and functional near visual acuity. The visual results were associated with high levels of spectacle independence and patient satisfaction.

Keywords: Extended Depth of Focus; Multifocal Intraocular Lens; Presbyopia; Cataract Extraction; Intraocular Lens Implantation

Abbreviations: EDOF: Extended depth of focus; IOL: Intraocular lens; CDVA: Corrected Distance Visual Acuity; UDVA: Uncorrected Distance Visual Acuity; UIVA: Uncorrected Intermediate Visual Acuity; UNVA: Uncorrected Near Visual Acuity; MRSE: Manifest Refraction Spherical Equivalent