Federico Hahn* and Angel Hernandez
Received: January 18, 2021 Published: January 26, 2021
Corresponding author: Rohit Kumar, Department of Electrical Engineering, Govind Ballabh Pant University of Agriculture and Technology, Pantnagar, Uttarakhand, India
DOI: 10.32474/ARME.2021.03.000152
Mexico is the world largest producer of cactus pear (Opuntia spp.) and is searching for new processes that allow to export them. The fruit is rich in nutrients but is highly perishable having ambient shelf life of 9 days. Cauterization and cryo-cauterization techniques have increased shelf life to 2 and 3 months without refrigeration. An automatic system was developed to flip the fruit towards the dry-ice wall inside a chamber. A horizontal actuator pushed the container to cauterize the fruit. The entire cauterizing process for each fruit lasted 23 seconds. By exchanging the dry-ice wall every 500 fruits, a 100% cauterizer efficiency was achieved.
Keywords: Automatic Chamber; Cauterization; Prickle Pear; embedded system
Cactus pear (Opuntia spp.) is a fruit produced in arid and
semi-arid regions around the world [1]. Mexico is the world’s
largest producer of cactus pear (Opuntia spp.) with 79.4% of world
production, and with 49,165 ha under cultivation [2]. Italy is now
the world’s largest exporter of cactus pear to the European Union
(EU), producing about 87 thousand tons annually in Sicily, which
corresponds to 96% of the total Italian harvest [3]. Cactus pear is
generally consumed fresh, but is highly perishable, showing high
incidence of spots and rotting after 9 days. After 20 days at ambient
conditions, almost 70% of the fruit was visibly damaged [4]. By
cooling prickle pears to 10 °C, shelf life increased to 6 weeks [5].
Fresh cactus pear shelf life can be increased to 32 days in modified
atmosphere packaging with less than 20 kPa CO2 [6]. A cauterizer
cut and seal 120 pieces of fruit per hour [7]; cuts were made close
to the cactus cladode at 150 °C during harvest, destroying thorns.
After 2 months of storage, 78% of the pears were unspoiled.
The application of uniform heat treatments has been effective in
controlling postharvest diseases, but can damage the treated fruit
tissue if not applied carefully. Excessive heating period may damage
the fruit, while insufficient heating may leave non-sterilized surface
segments [8]. Further developments of cauterizer machines by
Hahn [9-12] applied heat to sliced pears. After applying a constant
pressure of 100 kPa at 200 °C during 30 s to harvested cactus pears
increased shelf life to 2 months, controlling effectively postharvest
diseases [9]. However, heat application is expensive when many
fruits are cauterized. A cryo-cauterization process used a pneumatic
robotic gripper to press a cactus pear against a dry-ice wall within
a thermally isolated chamber. Fruit cryocauterizing at 150kPa for
15s increased shelf life to 90 days, keeping 86% of marketable fruit
[11].
Automation of agriculture tasks have improved pre-harvest,
harvest and post-harvest stages. Machine vision sorting of fruits
presents advantages of high accuracy, precision and processing
speed [13]. Non-contact detection makes grading and sorting free
of mankind diseases. Fruits and vegetables produced in farms are
sorted according to quality and maturity levels and decisions taken
of the market it can be sent on the basis of transportation delay
[14]. Post-harvesting operations require quality detection [15] and
skin defects [16]. A pepper robotic harvester system [17] avoiding
stem and fruit damage would be highly successful. Although food
processing methods extend the shelf life of fruit and vegetable
products, fresh-cut produce may lead to flavor loss, discoloration,
rapid softening, and increased rate of vitamin loss [18]. Emerging
smart packaging reduce losses, maintain quality, add value and
extend shelf-life of agricultural produce [19]. It alerts the consumer
from contamination of pathogens, pesticide residues or food
degradation in food packaging products [20]. Intelligent packaging
with nano sensors senses and informs the condition of the product to provide information about quality during transport, distribution,
and storage [21]. This technology may also be used to detect
adverse reactions in consumers after taking food such as gluten,
peanuts and tree nuts [22]. Automation for the application of these
sensors is considered a future close innovation. In this paper, an
automatic system used for prickle pear cryo cauterization within
a very small chamber was developed. The chamber size obeys to
the rapid melting of dry-ice caused by environmental conditions.
A minimum number of operations is required and the system
efficiency evaluated to cauterize 120 pears per hour.
The top-surface sliced prickly pear is moved within a container into the cryo-cauterized chamber (Figure 1) by means of a conveyor belt. This band transports the fruits in a direction parallel to the dry-ice wall where cauterization takes place. A trapezoidal metal container resembles a porcelain coffee mug and holds the prickly pear (Figure 2) whose flat base stops at the bottom. The container base is 3mm thick (Figure 2) and has force sensor in between the base and the prickle pear. The system mechanism has to perform the following functions:
1. Detect when the prickle pear is present within the metal
container.
2. Rotate it 9° counterclockwise.
3. Displace it against the dry ice wall.
4. Return it and deposit it to the original band.
During the first stage, a conveyor belt transports the prickle
pear to the cauterizer chamber rising the door in the left side. At
the same time, it opens another door to exit the previous cauterized
pear. For the second function, the mechanism used an actuator
(A1) to flip the metal container (Figure 2). The linear piston or
actuator (mod. LA 14, LINAK, Denmark) is characterized by its
compact size being ideal for this chamber having a limited amount
of space available. The aluminum actuator is used in harsh and cold
environments up to -40 °C. A metal ring with a sectional groove is
located at the container base (Figure 2). The lower piston plunger
enters the groove and as it moves upwards, it turns the container
base (Figure 3); a tip rod flips the container as the piston rises. After
45 or 50 degrees of rotation, the actuator rod gets out of the groove
and the container falls by gravity. A small compression spring stops
the container reaching its end point over a pair of rails (Figure 3).
The third operation requires of a second electric actuator (A2) that
pushes the container together with the fruit until it reaches the
dry-ice wall, where it will stay pressurizing the pear for 15 seconds.
Fruit moves at most 5cm over two rails before it reaches the dry-ice
wall. The electric actuator (mod. LA 25, LINAK, Denmark) presents
a speed of 20mms-1, withstanding cold temperatures of -25 °C.
The fourth operation returns the container with a 12 VDC round electromagnet mounted at the end of the piston rod. After activating the 30mm diameter electromagnet, the container remained fixed and forced to return. A micro switch (MS1) was activated at the runend, and the voltage supplied to the electromagnet was interrupted releasing the container that felt to initial band position. The voltage supplied to the horizontal actuator was also cut.
Once implemented the chamber with its mechanisms, the sensors for automation were obtained. The process begins when the conveyor belt is turned on, which will enter the cauterization chamber and an inductive presence sensor (SI1) will detect when it is in the desired position. This sensor will serve to turn off the band and at the same time it will feed the actuator (A1) so that its rod moves upward, initiating the rotation of the container. The rod or plunger will come out from the container base and an inductive sensor (SI2) provides a signal to limit its travel. The container flips unto a pair of rails and a capacitive sensor (SC3) detects its presence, and its signal activates the horizontal actuator (A2). Its plunger with the electromagnet at its end pushes the fruit container towards the dry-ice wall. The force sensor (SF) starts measuring when the prickle pear touches the wall. The contact is maintained for 15 seconds and at the same time a negative voltage is applied for 5 seconds to the vertical actuator so that it returns to its initial position. Force sensor resistors (FSR) provide a resistance that is inversely proportional to the applied force and can measure grabbing and pressing. Flex Force sensors enable non-intrusive static and dynamic force measurements presenting better force linearity, hysteresis and temperature sensitivity than other thinfilm force sensors [23-25]. Voltage processing was done through a Wheatstone bridge having the variable flex force sensor in one arm as in the data glove [25]. The output voltage is compared and the output provided to the embedded system. At the end of the cauterizer time, the electromagnet (EM) is activated and the polarity of the horizontal actuator is reversed until it touches a micro switch (MS1). When MS1 is actuated, the electromagnet and the horizontal piston are turned-off allowing the container to fall by gravity onto the conveyor belt. The band turns on and a new cycle starts taking out of the chamber the cauterized fruit and putting in the prickly pear to be treated. Figure 4 shows the cauterizer system timing chart for automation.
The control system employs only digital inputs and outputs and all the outputs were connected to port 1 of the ATM8951 microcontroller (Figure 5). Three output pins of port-1 were connected to H-Bridge 1 (P1.0, P1.1 and P1.2) and another 3 pins to H-Bridge 2 (P1.3, P1.4 and P1.5). The H-Bridge 1 and H-Bridge 2 controls the horizontal and vertical actuator motors, respectively. The three control terminals of H-Bridge 1 are enable, IN1 and IN2. If H-Bridge 2 is selected (EN = 1), the actuator rod will move upwards when IN1 = 1 and IN2 = 0. The actuator motor stops by setting IN1 = IN2 = 0, and if IN1 = 0 and IN2 = 1, the actuator will move the rod downwards. The horizontal actuator will move the container towards the dry-ice wall with IN1 = 1 and IN2 = 0. In the case of having IN1 = 0 and IN2 = 1, the actuator will return back. The H-Bridge used was MC33HB2001 (NXP Semiconductors, Netherlands) as it can handle 10A and 34 V. A N-Channel Power MOSFET (NTP5860NL, Semiconductor Industries, USA) turned-on the electromagnet once P1.7 applied a 5-volt signal. The routine starts when the fruit is detected by the inductive detector. The signal interrupt the microcontroller turning-on the vertical actuator (Figure 5). The embedded routine starts polling and asks whether the vertical plunger has arrived to its limit position where the inductive detector (SI2 P2.0) detects it. The vertical actuator motor is stopped and checks if the pear is over the rails; the capacitor sensor will detect it (SC3 P2.3). The microcontroller moves the horizontal actuator and when the force sensor provides a 5 V signal, the controller provides a cauterizing timing of 15 seconds. Otherwise it waits until FS changes to 1. After the 15 seconds, the container together with the pear returns once the electromagnet is activated by the MOSFET (pin 1.7). The controller waits until SW1=1 (P2.5) to stop the actuator.
The container diameter was fixed based on the maximum equatorial measurement of the prickle pears. Two hundred fruits (Opuntia var. Amarilla & Cristalina) commonly grown in Mexico were harvested and weighted. Prickle pears variety “Amarilla” were lighter 96±5.3g having a diameter ranging between 4.9 and 5.5cm. Prickle pears var “Cristalina” were heavier 197±13.1g having a diameter ranging between 5 and 5.7cm. Maximum fruit length was 8cm for both varieties. These values agree with the study carried by Corrales and Hernandez using the same varieties [26]. Considering these values, the container was designed to be 5.5cm long with a diameter of 5.7cm.
The total weight of the container plus the prickly pear was less
than 500 grams considering that the deposit weighs 285 grams.
Although smaller pistons can be employed, it was decided to work
with ones already proven for use in hospitals. These actuators have
motors that work at 12 or 24 VDC and handle loads of up to 750N.
The current obtained at 12 VDC was 200 mA, being half that when
operating at 24 VDC. Linear rod speed was the main parameter
to study since it could affect container rotation and fruit stability.
An experiment was carried out to determine the best operation
at three different speeds (25mms-1, 35mms-1 and 45mms-1). Fifty
fruits within containers were rotated for each speed after lifting
the container base with the actuator. The two quicker speeds used
a spindle pitch of 4mm, while the low speed worked with a 2mm
pitch. Twenty-one prickly pears (42%) felt in between the rails
when the rod moved at the highest speed. As speed was reduced to
35mms-1 only 6 (12%) prickly pears came out from the container.
With a speed of 25mms-1 the container rotated slower and no
pears were ejected from the container. The LA 25 actuator used as
horizontal actuator used a 24 VDC power supply, being the current
used 1.8 A during pressing against the wall and 0.9 during container
horizontal displacement. The current of 1.8 A is obtained when a
force of 1200N is applied. A 9mm pitch was employed and its push
linear speed reached 8mms-1. The linear speed without such force is
10mms-1, so it takes 3 seconds to move the container 30mm.
For the final evaluation, three thousand fruits were used, which
were cauterized in groups of one thousand and sliced manually in
groups of twenty. The total time required to cauterize a prickly pear
was 23 seconds being 15 seconds the fruit contact against the dryice
wall. The vertical actuator stepped-up 50mm in two seconds at a
speed of 25mms-1. At that moment the prickly pear felt into the rails
and after another second the horizontal actuator pushed the fruit
against the cauterizing wall. Two additional seconds were required
to return of the prickly pear and its repositioning on the conveyor
belt. The electromagnet only worked one second out of every 20
seconds giving a 13% duty cycle which kept its magnet temperature
under control; the low temperature of the chamber was also helpful
to avoid heating. The efficiency of cauterization in the first 20
prickly pears was of 8%, so 4 fruits were not properly cauterized.
The shape of these prickle pears did not allow them to contact the
flex sensor at the container end. Therefore, no reading was obtained
and the cauterization timing provided by the microcontroller was
null; after a minute the fruit was still inside the chamber contacting
the dry-ice wall. Only prickle pears with equatorial diameters
smaller than 55mm were used in the first experiment with 1000
fruits. The processing of the first 1000 fruits took a little more than
500 minutes (4 hours and 20 minutes). An audible alarm was added
to determine if there was no measurement with the force sensor. A
proper 92% cauterization efficiency resulted and 80 prickly pears
were not properly cauterized. The electrical connection between the
container and the sliding cable for the force sensor output was not
well made or it resulted in false contacts in 68 fruits; After hearing
the alarm the pears were removed. The other 12 prickly pears did
not make adequate contact with the dry ice due to a slightly tilted
cut that came from a previous operation outside the chamber.
With the other group of 1000 prickle pears, the force sensor and
the external electrical contacts were removed. The period to move
the horizontal actuator was increased to 18 seconds. A total of 987
prickle pears with precise cuts at the top were properly sealed and the last 13 fruits had problems as the dry-ice block melted,
becoming thinner. As the block becomes thinner it is unable to
withstand the cauterizer pressure. It is important to change the
15mm thick dry-ice plate every 500 prickly pears, since at the end
of the cauterization of 500 fruits it is only 3mm thick. Another one
thousand pears were introduced to the chamber, but the dry-ice
plate was exchanged twice; a proper cauterizer efficiency of 100%
was obtained. This result indicates that three systems can work in
parallel, which would triple the amount of cauterized prickly pears
without reducing the dry-ice wall thickness so quickly.
This work shows an automatic system for cauterizing prickle pears which will extend the shelf life up to 3 months. The automatic equipment can cauterize 1000 fruits in 4 and a half hours, being each fruit processed in 23 seconds. The dry-ice block melts as every time a fruit enters the chamber it heats it up. As it melts it becomes thinner and it will not be able to withstand the cauterizer pressure. The embedded system used to cauterize fruits was simple and the flex force sensor was removed as it generates some contact problems; as well signal connections should be wireless. Both actuators worked precisely under -5 °C harsh conditions.
I would like to acknowledge all the technical staff of the University that helped to build the prototype.
Bio chemistry
University of Texas Medical Branch, USADepartment of Criminal Justice
Liberty University, USADepartment of Psychiatry
University of Kentucky, USADepartment of Medicine
Gally International Biomedical Research & Consulting LLC, USADepartment of Urbanisation and Agricultural
Montreal university, USAOral & Maxillofacial Pathology
New York University, USAGastroenterology and Hepatology
University of Alabama, UKDepartment of Medicine
Universities of Bradford, UKOncology
Circulogene Theranostics, EnglandRadiation Chemistry
National University of Mexico, USAAnalytical Chemistry
Wentworth Institute of Technology, USAMinimally Invasive Surgery
Mercer University school of Medicine, USAPediatric Dentistry
University of Athens , GreeceThe annual scholar awards from Lupine Publishers honor a selected number Read More...